Literature

Decades of chromatography research done with DryLab®.

Browse through a complete list of over 280 publications that have been published using DryLab®.

Showing 81–100 of 210 results for "reverse phase"

Journal of Chromatography A · 2000

Reversed-phase separation of achiral isomers by varying temperature and either gradient time or solvent strength

Lloyd R. Snyder, John W. Dolan

The separation of several isomer pairs of widely varied structure was studied as a function of changes in temperature, gradient time, mobile phase pH, column type (“monomeric” vs. “polymeric” C18-silica) and organic solvent (methanol vs. acetonitrile). General conclusions are drawn which may prove useful in future attempts at the separation of these and other achiral isomers.

Journal of Chromatography A · 2024

Revisiting column selectivity choices in ultra-high performance liquid chromatography–Using multidimensional analytical Design Spaces to identify column equivalency

Arnold Zöldhegyi, Krisztián Horváth, Róbert Kormány

Current guides and column selection system (CSS) platforms can provide some helpful insights with regard to the selection of alternative phases. Their practical reliability however, can also turn out to be questionable, especially considering the lack of detailed specifics, such as a clear definition of points of equivalence—appropriate running conditions under which the given analytical mixture can be satisfactorily resolved on various stationary phases. In this context, the use of multivariate modeling tools can be highly beneficial. These tools, when applied systematically, are ideal for uniquely characterizing complex LC-separation systems, a fact supported by numerous peer-reviewed papers. Revisiting our earlier work [1] and the applied systematic workflow [2], we used a Design Space modeling software (DryLab), with the main focus on building and comparing 3-dimensional separation models of amlodipine and its related impurities to identify shared method conditions under which columns are conveniently interchangeable. Our study comprised 5, C18-modified ultra-high performance liquid chromatography (UHPLC) columns in total, in some cases with surprising results. We identified several equivalences between the Design Spaces (DSs) of markedly different columns. Conversely, there were cases where, despite the predicted similarities in column data, the modeled DSs demonstrated clear differences between the selected stationary phases.

Journal of Pharmaceutical and Biomedical Analysis · 2017

Analysis of recombinant monoclonal antibodies in hydrophilic interaction chromatography: A generic method development approach

Balázs Bobály, Valentina D’Atri, Alain Beck, Davy Guillarme, Szabolcs Fekete

Hydrophilic interaction liquid chromatography (HILIC) is a well-established technique for the separation and analysis of small polar compounds. A recently introduced widepore stationary phase expanded HILIC applications to larger molecules, such as therapeutic proteins. In this paper, we present some generic HILIC conditions adapted for a wide range of FDA and EMA approved recombinant monoclonal antibody (mAb) species and for an antibody-drug conjugate (ADC). Seven approved mAbs possessing various isoelectric point (pI) and hydrophobicity as well as a cysteine conjugated ADC were used in this study. Samples were digested by IdeS enzyme and digests were further fragmented by chemical reduction. The resulting fragments were separated by HILIC. The main benefit of HILIC was the separation of polar variants (glycovariants) in a reasonable analysis time at the protein level, which is not feasible with other chromatographic modes. Three samples were selected and chromatographic conditions were further optimized to maximize resolution. A commercial software was used to build up retention models. Experimental and predicted chromatograms showed good agreement and the average error of retention time prediction was less than 2%. Recovery of various species and sample stability under the applied conditions were also discussed.

Journal of Pharmaceutical and Biomedical Analysis · 2015

Method development for the separation of monoclonal antibody charge variants in cation exchange chromatography, Part I: Salt gradient approach

Szabolcs Fekete, Alain Beck, Jenő Fekete, Davy Guillarme

Ion exchange chromatography (IEX) is a historical technique widely used for the detailed characterization of therapeutic proteins and can be considered as a reference and powerful technique for the qualitative and quantitative evaluation of charge variants. When applying salt gradient IEX approach for monoclonal antibodies (mAbs) characterization, this approach is described as time-consuming to develop and product-specific. The goal of this study was to tackle these two bottle-necks. By modeling the retention of several commercial mAbs and their variants in IEX, we proved that the mobile phase temperature was not relevant for tuning selectivity, while optimal salt gradient program can be easily found based on only two initial gradients of different slopes. Last but not least, the dependence of retention vs. pH being polynomial, three initial runs at different pH were required to optimize mobile phase pH. Finally, only 9h of initial experiments were necessary to simultaneously optimize salt gradient profile and pH in IEX. The data can then be treated with commercial modeling software to find out the optimal conditions to be used, and accuracy of retention times prediction was excellent (less than 1% variation between predicted and experimental values). Second, we also proved that generic IEX conditions can be applied for the characterization of mAbs possessing a wide range of pI, from 6.7 to 9.1. For this purpose, a strong cation exchange column has to be employed at a pH below 6 and using a proportion of NaCl up to 0.2M. Under these conditions, all the mAbs were properly eluted from the column. Therefore, salt gradient CEX can be considered as a generic multi-product approach.

Journal of Pharmaceutical and Biomedical Analysis · 2013

Classification of LC columns based on the QSRR method and selectivity toward moclobemide and its metabolites

Alina Plenis, Ilona Olędzka, Tomasz Bączek

This paper focuses on a comparative study of the column classification system based on the quantitative structure-retention relationships (QSRR method) and column performance in real biomedical analysis. The assay was carried out for the LC separation of moclobemide and its metabolites in human plasma, using a set of 24 stationary phases. The QSRR models established for the studied stationary phases were compared with the column test performance results under two chemometric techniques – the principal component analysis (PCA) and the hierarchical clustering analysis (HCA). The study confirmed that the stationary phase classes found closely related by the QSRR approach yielded comparable separation for moclobemide and its metabolites. Therefore, the QSRR method could be considered supportive in the selection of a suitable column for the biomedical analysis offering the selection of similar or dissimilar columns with a relatively higher certainty.

LC GC · 1998

Reversed-Phase Gradient Elution: How to Get Better Results with Less Work

Imre Molnár, Lloyd R. Snyder, John W. Dolan

HPLC 2006 · 2006

Fundamentals of Reversed Phase Chromatography: Solvophobic Theory Redux

Anant Vailaya

LC GC · 1988

Developing a Gradient Elution Method for Reversed-Phase HPLC

Lloyd R. Snyder, J. W. Dolan

Application of DryLab G method development strategy to a real sample

LC GC · 1985

Selecting Column Conditions for Reversed-Phase HPLC Separation II. Column Configuration and Column Evaluation

Lloyd R. Snyder, P.E. Antle

HPLC of Biological Macromolecules: Methods and Application · 1990

The 30S Ribosomal Proteins as a Model for the Optimized Separation of Large Biomolecules by Reversed-Phase HPLC

Karen M. Gooding, Fred E. Regnier, B.F.D. Ghrist, B.S. Cooperman, Lloyd R. Snyder

Application of DryLab G/plus to the separation of the 30S ribosomal proteins

Journal of Chromatography · 1989

Prediction of retention times in ion-exchange chromatography

Tatsuru Sasagawa, Yasuhiro Sakamoto, Tsukasa Hirose, Tatsunari Yoshida, Yoshimi Kobayashi, Yoshihiro Sato, Kyoko Koizumi

A method for prediction ion-exchange isocratic capacity factors from two initial gradient runs is developed. This does not assume so-called linear solvent strength (LSS) conditions, which cause significant errors in k'(C) vs. C relationships in ion-exchange chromatography. The errors associated with this approach and the LSS model are examined. The present approach allows a more accurate prediction of isocratic capacity factors for ion-exchange chromatography. Experimental application of the method to a variety of compounds, including peptides, polynucleotides and polysaccharides, separated by ion-exchange chromatography is described.

Journal of Chromatography A · 1996

Initial experiments in high-performance liquid chromatographic method development II. Recommended approach and conditions for isocratic separation

J. A. Lewis, Lloyd R. Snyder, John W. Dolan

Initial method development experiments for both neutral and ionic samples are best carried out with reversed-phase high-performance liquid chromatography (HPLC) using acetonitrile-methanol-buffer mobile phases. The preceding paper (Part I) suggests the use of an acetonitrile-buffer gradient to start method development. In this paper, optimum conditions for this first separation are discussed. Sequential method development experiments plus computer simulations are then used to obtain a final HPLC method. In this connection, we have examined how many experiments are required for reliable predictions of ternary-solvent retention. Three experiments are sufficient to predict isoeluotropic retention for methanol-acetonitrile-buffer ternaries where solvent strength does not vary, but five experiments are required for ternaries that contain tetrahydrofuran.

Analytica Chimica Acta · 2015

Effect of temperature on acid–base equilibria in separation techniques. A review

Leonardo G. Gagliardi, Marcos Tascon, Cecilia B. Castells

Studies on the theoretical principles of acid–base equilibria are reviewed and the influence of temperature on secondary chemical equilibria within the context of separation techniques, in water and also in aqueous-organic solvent mixtures, is discussed. In order to define the relationships between the retention in liquid chromatography or the migration velocity in capillary electrophoresis and temperature, the main properties of acid–base equilibria have to be taken into account for both, the analytes and the conjugate pairs chosen to control the solution pH. The focus of this review is based on liquid–liquid extraction (LLE), liquid chromatography (LC) and capillary electrophoresis (CE), with emphasis on the use of temperature as a useful variable to modify selectivity on a predictable basis. Simplified models were evaluated to achieve practical optimizations involving pH and temperature (in LLE and CE) as well as solvent composition in reversed-phase LC.

TrAC Trends in Analytical Chemistry · 2018

Critical review of reports on impurity and degradation product profiling in the last decade

Sándor Görög

Drug impurity and degradation profiling mean the detection, structure elucidation and quantitative determination of impurities and degradation products in bulk drug materials and pharmaceutical formulations. This is today one of the most important fields of activities in pharmaceutical analysis. The reason for this is that unidentified, potentially toxic impurities are health hazards, and in order to increase the safety of drug therapy, impurities should be identified and determined by selective methods. The aim of this review is to characterise the state-of-art in the field of impurity and degradation profiling of drugs based on papers published in the last decade. The separation and determination of impurities and degradants with a known structure are discussed, but emphasis is placed on the structure elucidation and determination of new (unknown) impurities and degradation products by off-line and on-line chromatographic–spectroscopic methods. The analytical aspects of enantiomeric purity of chiral drugs are also discussed.

Journal of Chromatography A · 2002

Lipophilicity and pKa estimates from gradient high-performance liquid chromatography

Roman Kaliszan, Piotr Haber, Tomasz Bączek, Danuta Siluk, Klara Valko

The linear-solvent strength (LSS) model of gradient elution has been applied to estimate parameters of lipophilicity and acidity of a series of drugs and model chemicals. Apparent pKa values and log kw values for individual analytes were determined in 2–3 gradient runs. The first experiment (or first two experiments) uses a wide-range organic modifier gradient with pH chosen for suppressed ionization of the analyte. The result of this experiment allows an estimate of contents of organic modifier of the mobile phase (%B) providing the required retention coefficient, k, for the non-ionized analyte. The following experiment is carried out with the latter %B and a pH-gradient of the aqueous component of the eluent that is sufficient to overlap the possible pKa-value of the analyte. The initial pH of the buffer used to make the mobile phase is selected to insure that the analyte is in non-ionized form. The resulting retention time allows an estimate of pKa in a solvent of the selected %B. At the same time, estimates of log kw can also be obtained. The log kw parameter obtained from gradient HPLC by the approach proposed correlated well with the corresponding value obtained by standard procedure of extrapolation of retention data determined in a series of isocratic measurements. Correlation between log kw and the reference parameter of lipophilicity, log P, was very good for a series of test analytes and satisfactory for a structurally diverse series of drugs. The approach supported with specific detection procedures can be recommended for fast screening of lipophilicity of individual components of complex mixtures like those produced by combinatorial chemistry. The values of pKa obtained in a study were found to correlate with the literature pKa data determined in water for a set of aniline derivatives studied. In case of a series of drugs the correlation was less than moderate if the general procedure of pKa determination was applied.

J Chromatogr · 1989

Practical approach for high-performance liquid chromatographic method development: assaying synthetic intermediates of a leukotriene inhibitor

John Fulper

High-performance liquid chromatographic (HPLC) methods for analyzing new drugs and their synthetic intermediates are needed as the synthesis is optimized and scaled up from making milligram amounts for initial evaluation of biological activity to producing kilogram amounts of the drug for thorough testing purposes. The most efficient solution is a single HPLC method that can be used for each step of the synthesis. A practical approach for the development of a single HPLC method is the use of computer-assisted method development to maximize the resolution within a reasonable analysis time. The computer program DryLab I was used in the development of an HPLC assay for the synthetic intermediates of a leukotriene inhibitor. The use of DryLab I with binary mixtures of organic solvents in the organic portion of reversed-phase HPLC systems is reported. With the retention data from two initial analyses, resolution can be optimized as a function of solvent strength.

Journal of Chromatography · 1992

Computer simulation as a tool for the rapid optimization of the high-performance liquid chromatographic separation of a tryptic digest of human growth hormone

R. C. Chloupek, W. S. Hancock, L. R. Snyder

Computer simulation was used to optimize the separation of a tryptic digest of recombinant human growth hormone using reversed-phase high-performance liquid chromatography in a gradient mode. DryLab G/plus software modelled the retention behavior of the complex tryptic digest mixture as a function of gradient conditions, based on data from two experimental gradient runs. The theoretical optimum separation conditions were rapidly obtained and reproduced experimentally. Resolution did not simply increase as gradient steepness was decreased, rather, an intermediate gradient time provided maximum sample resolution. The simulation results also indicate that the method is reasonably rugged, with little change in the separation expected for different high-performance liquid chromatography systems, and changes in the separation can be compensated by a change in the gradient steepness. Computer simulation can also be useful to quickly reoptimize conditions for a new column, if it fails to provide the same separation.

Journal of Pharmaceutical and Biomedical Analysis · 2014

Reliability of simulated robustness testing in fast liquid chromatography, using state-of-the-art column technology, instrumentation and modelling software

Róbert Kormány, Jenő Fekete, Davy Guillarme, Szabolcs Fekete

The goal of this study was to evaluate the accuracy of simulated robustness testing using commercial modelling software (DryLab) and state-of-the-art stationary phases. For this purpose, a mixture of amlodipine and its seven related impurities was analyzed on short narrow bore columns (50×2.1mm, packed with sub-2μm particles) providing short analysis times. The performance of commercial modelling software for robustness testing was systematically compared to experimental measurements and DoE based predictions. We have demonstrated that the reliability of predictions was good, since the predicted retention times and resolutions were in good agreement with the experimental ones at the edges of the design space. In average, the retention time relative errors were <1.0%, while the predicted critical resolution errors were comprised between 6.9 and 17.2%. Because the simulated robustness testing requires significantly less experimental work than the DoE based predictions, we think that robustness could now be investigated in the early stage of method development. Moreover, the column interchangeability, which is also an important part of robustness testing, was investigated considering five different C8 and C18 columns packed with sub-2μm particles. Again, thanks to modelling software, we proved that the separation was feasible on all columns within the same analysis time (less than 4min), by proper adjustments of variables.

Chromatography Today · 2013

Chromatography Modelling in High Performance Liquid Chromatography Method Development

Imre Molnár, Róbert Kormány

This article discusses the development of chromatography modelling of the last 30 years from the first software package for calculating resolution and capacity factors to the visual modelling of chromatograms for testing peak movements with altering elution conditions. Different approaches are discussed, such as retention modelling based on measurements, others based on molecular structure or on statistical considerations. The state-of-the-art will be demonstrated with a few applications of industrial importance.

Software-assisted method development in high performance liquid chromatography · 2019

Modeling of HPLC Methods Using QbD Principles in HPLC

Szabolcs Fekete, Imre Molnár, Imre Molnár, Hans-Jürgen Rieger, Róbert Kormány

HPLC method modeling is becoming a powerful tool to be used in the communication about method quality in HPLC between different labs, different companies, and between companies and regulatory agencies. The understanding of simple rules of peak movements will facilitate the development of new drugs, which are badly needed for smaller patient populations. The new features of HPLC modeling software, such as 3D resolution map, the modeled robustness testing, a practicable method transfer, or a method knowledge management offer a closed loop of all information about the birth and practical use of a method, and it further suggests the use of such software solutions in regulated laboratories to make analyst's life easier-especially in the pharmaceutical industry.