Showing 1–20 of 50 results for "ion-exchange"

Journal of Chromatography · 1989

Prediction of retention times in ion-exchange chromatography

Tatsuru Sasagawa, Yasuhiro Sakamoto, Tsukasa Hirose, Tatsunari Yoshida, Yoshimi Kobayashi, Yoshihiro Sato, Kyoko Koizumi

A method for prediction ion-exchange isocratic capacity factors from two initial gradient runs is developed. This does not assume so-called linear solvent strength (LSS) conditions, which cause significant errors in k'(C) vs. C relationships in ion-exchange chromatography. The errors associated with this approach and the LSS model are examined. The present approach allows a more accurate prediction of isocratic capacity factors for ion-exchange chromatography. Experimental application of the method to a variety of compounds, including peptides, polynucleotides and polysaccharides, separated by ion-exchange chromatography is described.

Analytical Chemistry · 1977

Enhancement of retention by ion-pair formation in liquid chromatography with nonpolar stationary phases

Csaba Horváth, Wayne Melander, Imre Molnár, Petra Molnár

In Ion-pair reversed-phase chromatography, the retention of ionized analytes on a nonpolar bonded stationary phase is enhanced by the presence of a "hydrophobic" counterlon (hetaeron) in the mobile phase. Either ion-pair formation in the mobile phase with relatively strong retention of the complex or the conversion of the stationary phase into an ion-exchanger may explain the phenomenon. Analysis of the pertinent equilibria shows that the observed hyperbolic or parabolic dependence of the capacity factors on the hetaeron concentration cannot shed light on the mechanism. The experimental data obtained for the retention of catecholamlnes by using C4-C10 alkyl sulfates and other similar hetaerons in a wide concentration range, however, could be mechanistically interpreted from the chain length dependence of the parameters for the relationship between the capacity factors and hetaeron concentration. Although the results clearly demonstrate that in the system investigated, ion-pair formation governs retention, ion-exchange mechanism can be operative under certain conditions. Changes in retention upon addition of salt to the eluent are treated both theoretically and experimentally. The effect of organic solvents on the behavior of the chromatographlc system is discussed in view of the proposed theory.

Journal of Chromatography · 1987

Predicting bandwidth in the high-performance liquid chromatographic separation of large biomolecules: II. A general model for the four common high-performance liquid chromatography methods

M. A. Stadalius, B. F. D. Ghrist, L. R. Snyder

A general model for describing gradient elution separations of peptides and proteins by reversed-phase high-performance liquid chromatography (HPLC) has been presented previously. This model has now been modified so that it can be applied to any of the four HPLC methods used for separating biological macromolecules: reversed-phase, ion-exchange, hydrophobic-interaction and size-exclusion chromatography, carried out in either an isocratic or gradient elution mode. The role of sample molecule structure and the particular column used has been further studied, so that previous empirical parameters for different column/sample choices can now be estimated from three physical properties of the sample and the column: (a) sample molecular weight, (b) native vs. denatured sample, (c) column packing pore diameter. This eliminates much of the empiricism of our preceding model, and minimizes the number of experimental runs now required in order to apply the model in practice. The final model has been tested for (a) several hundred runs involving peptides and proteins in the molecular weight range 600–162000, (b) all four of these HPLC methods, (c) in both isocratic and gradient elution modes, and (d) using data from several different laboratories (including our own). The model is able to predict bandwidth in HPLC separations of proteins and peptides with an accuracy of ±17% (1 standard deviation), for the case of “well-behaved” separations. Separations that are not “well-behaved” will give wider bands than predicted by the model.

Journal of Pharmaceutical and Biomedical Analysis · 2015

Method development for the separation of monoclonal antibody charge variants in cation exchange chromatography, Part I: Salt gradient approach

Szabolcs Fekete, Alain Beck, Jenő Fekete, Davy Guillarme

Ion exchange chromatography (IEX) is a historical technique widely used for the detailed characterization of therapeutic proteins and can be considered as a reference and powerful technique for the qualitative and quantitative evaluation of charge variants. When applying salt gradient IEX approach for monoclonal antibodies (mAbs) characterization, this approach is described as time-consuming to develop and product-specific. The goal of this study was to tackle these two bottle-necks. By modeling the retention of several commercial mAbs and their variants in IEX, we proved that the mobile phase temperature was not relevant for tuning selectivity, while optimal salt gradient program can be easily found based on only two initial gradients of different slopes. Last but not least, the dependence of retention vs. pH being polynomial, three initial runs at different pH were required to optimize mobile phase pH. Finally, only 9h of initial experiments were necessary to simultaneously optimize salt gradient profile and pH in IEX. The data can then be treated with commercial modeling software to find out the optimal conditions to be used, and accuracy of retention times prediction was excellent (less than 1% variation between predicted and experimental values). Second, we also proved that generic IEX conditions can be applied for the characterization of mAbs possessing a wide range of pI, from 6.7 to 9.1. For this purpose, a strong cation exchange column has to be employed at a pH below 6 and using a proportion of NaCl up to 0.2M. Under these conditions, all the mAbs were properly eluted from the column. Therefore, salt gradient CEX can be considered as a generic multi-product approach.

Journal of Chromatography · 1987

Predicting bandwidth in the high-performance liquid chromatographic separation of large biomolecules: I. Size-exclusion studies and the role of solute stokes diameter versus particle pore diameter

B. F. D. Ghrist, M. A. Stadalius, Lloyd R. Snyder

Column plate numbers, N, were measured for 12 different proteins as a function of mobile phase flow-rate in two gel filtration systems (either denaturing or non-denaturing conditions). These data were used to extend a previous model that predicts bandwidths in reversed-phase and ion-exchange chromatography. Restriction of diffusion of large molecules within column packing pores is now defined more precisely, with a single relationship describing this effect for both reversed-phase and size-exclusion chromatography (SEC) (and presumably other high-performance liquid chromatography systems). Separations by gel filtration (SEC) are now included in our general model. A total of 17 flow-rate studies were carried out, involving different proteins, columns and/or mobile phase conditions (denaturing or non-denaturing). Comparisons of plate numbers predicted by the model with experimental values were satisfactory in 15 out of 17 cases. The remaining two cases appear to represent “non-well-behaved” systems, where experimental bandwidths were higher than predicted values by more than 20%. Initial attempts at understanding the origin of these non-ideal effects are described.

Analyst · 2016

Computer assisted liquid chromatographic method development for the separation of therapeutic proteins

Eva Tyteca, Jean-Luc Veuthey, Gert Desmet, Davy Guillarme, Szabolcs Fekete

This review summarizes the use of computer assisted liquid chromatographic method development for the analytical characterization of protein biopharmaceuticals. Several modes of chromatography including reversed-phase liquid chromatography (RPLC), ion exchange chromatography (IEX), hydrophobic interaction chromatography (HIC) and some perspectives are discussed. For all these chromatographic modes, the most important variables for tuning retention and selectivity are exposed. Then, the retention models that were applied in the literature in RPLC, IEX and HIC are described and critically discussed. Finally, some representative examples of separation of therapeutic proteins and mAbs are shown, to illustrate the possibilities offered by the retention modeling approach. At the end, the reliability of the models was excellent, whatever the chromatographic mode, and the retention time prediction errors were systematically below 2%. In addition, a significant amount of time can be saved during method development and robustness testing.

Wiley · 2010

Equipment

Lloyd R. Snyder, J. J. Kirkland, John W. Dolan

Journal of Pharmaceutical and Biomedical Analysis · 2019

Tuning selectivity in cation-exchange chromatography applied for monoclonal antibody separations, part 1: Alternative mobile phases and fine tuning of the separation

Evelin Farsang, Amarande Murisier, Krisztián Horváth, Alain Beck, Róbert Kormány, Davy Guillarme, Szabolcs Fekete

Cation exchange chromatography (CEX) of therapeutic monoclonal antibodies is generally performed with either salt gradient (MES buffer + NaCl) or using commercial pH gradient buffer. The goal of this study was to find out some alternative buffer systems for CEX separation of mAbs, which may offer alternative selectivity, while maintaining similar peak shapes. Among the new buffers that were tested, (N-morpholino)ethanesulfonic acid (MES) / 1,3-diamino-2-propanol (DAP), and citric acid / 2-(cyclohexylamino)ethanesulfonic acid (CHES) systems were particularly promising, especially when combining them with a moderate salt gradient of NaCl. This two buffer system provides an equivalent or slightly better separation than the standard, mobile phases for therapeutic mAbs. It was also demonstrated that working with salt-mediated pH gradients, allows to extend the possibilities in method development, since the concentration of salt in the mobile phase has a significant impact on selectivity. Using HPLC modeling software (Drylab), it was possible to successfully develop CEX methods for authentic mAb samples within only 6 h, by optimizing the gradient steepness and salt concentration in the B eluent.

Journal of Chromatography · 1977

Separation of amino acids and peptides on non-polar stationary phases by high-performance liquid chromatography

Imre Molnár, Csaba Horváth

Microparticulate non-polar stationary phases, such as octadecyl-silica offer a rapid and efficient means for the separation of peptides and amino acids by high-performance liquid chromatography. Retention is attributed to hydrophobic interaction between the solutes and the hydrocarbonaceous functions covalently bound to the stationary phase surface. Consequently the species are eluted in the order of increasing hydrophobicity. Various peptide mixtures were analyzed by using gradient elution with increasing acetonitrile concentration in the eluent and monitoring the column effluent at 200 or 210 nm with an UV detector. The separation of angiotensins and enzymic digest of polypeptides illustrates the speed of the method which can be used to assay the purity of peptide hormones such as α-melanotropin and gramicidin or to analyze the composition of reaction mixtures involving peptides. The efficiency of the method is superior to that obtained on the conventionally used ion-exchanger columns, except for hydrophilic amino acids and peptides that are poorly retarded. Nevertheless, with a suitable ionic surfactant in the mobile phase, non-polar stationary phases can be used for the separation of these species as well.

Journal of Pharmaceutical and Biomedical Analysis · 2015

Method development for the separation of monoclonal antibody charge variants in cation exchange chromatography, Part II: pH gradient approach

Szabolcs Fekete, Alain Beck, Jenő Fekete, Davy Guillarme

The cation exhange pH gradient approach was evaluated for the characterization of 10 model monoclonal antibodies including panitumumab, natalizumab, cetuximab, bevacizumab, trastuzumab, rituximab, palivizumab, adalimumab, denosumab and ofatumumab. This work shows that retention and resolution can be modelled in cation exchange pH gradient mode, based on only four initial runs (i.e. two gradient times and two mobile phase temperature). Only 6h were required for a complete method optimization when using a 100mm×4.6mm strong cation exchange column. The accuracy of the predictions was excellent, with an average difference between predicted and experimental retention times of about 1%. The 10 model antibodies were successfully eluted in both pH and salt gradient modes, proving that both modes of elution can be considered as multi-product charge sensitive separation methods. For most of the compounds, the variants were better resolved in the salt gradient mode and the peak capacities were also higher in the salt gradient approach. These observations confirm that pH gradient approach may be of lower interest than salt gradient cation exchange chromatography for antibody characterization.

Journal of Pharmaceutical Sciences · 2020

Structure-Function Assessment and High-Throughput Quantification of Site-Specific Aspartate Isomerization in Monoclonal Antibody Using a Novel Analytical Tool Kit

Kaimeng Zhou, Xiang Cao, James Bautista, Zhi Chen, Neil Hershey, Richard Ludwig, Li Tao, Ming Zeng, Tapan K. Das

Isomerization of surface-exposed aspartic acid (Asp) in the complementarity-determining regions of therapeutic proteins could potentially impact their target binding affinity because of the sensitive location, and often requires complex analytical tactics to understand its effect on structure-function and stability. Inaccurate quantitation of Asp-isomerized variants, especially the succinimide intermediate, presents major challenge in understanding Asp degradation kinetics, its stability, and consequently establishing a robust control strategy. As a practical solution to this problem, a comprehensive analytical tool kit has been developed, which provides a solution to fully characterize and accurately quantify the Asp-related product variants. The toolkit offers a combination of 2 steps, an ion-exchange chromatography method to separate and enrich the isomerized variants in the folded structure for structure-function evaluation and a novel focused peptide mapping method to quantify the individual complementarity-determining region isomerization components including the unmodified Asp, succinimide, and isoaspartate. This novel procedure allowed an accurate quantification of each Asp-related variant and a comprehensive assessment of the functional impact of Asp isomerization, which ultimately helped to establish an appropriate control strategy for this critical quality attribute.

Journal of Chromatography A · 2024

Revisiting column selectivity choices in ultra-high performance liquid chromatography–Using multidimensional analytical Design Spaces to identify column equivalency

Arnold Zöldhegyi, Krisztián Horváth, Róbert Kormány

Current guides and column selection system (CSS) platforms can provide some helpful insights with regard to the selection of alternative phases. Their practical reliability however, can also turn out to be questionable, especially considering the lack of detailed specifics, such as a clear definition of points of equivalence—appropriate running conditions under which the given analytical mixture can be satisfactorily resolved on various stationary phases. In this context, the use of multivariate modeling tools can be highly beneficial. These tools, when applied systematically, are ideal for uniquely characterizing complex LC-separation systems, a fact supported by numerous peer-reviewed papers. Revisiting our earlier work [1] and the applied systematic workflow [2], we used a Design Space modeling software (DryLab), with the main focus on building and comparing 3-dimensional separation models of amlodipine and its related impurities to identify shared method conditions under which columns are conveniently interchangeable. Our study comprised 5, C18-modified ultra-high performance liquid chromatography (UHPLC) columns in total, in some cases with surprising results. We identified several equivalences between the Design Spaces (DSs) of markedly different columns. Conversely, there were cases where, despite the predicted similarities in column data, the modeled DSs demonstrated clear differences between the selected stationary phases.

World Scientific Publishing Europe Ltd · 2019

Software-assisted method development in high performance liquid chromatography

Imre Molnár, Szabolcs Fekete

"This handbook gives a general overview of the possibilities in recent developments in chromatographic retention modeling. As a result of the latest developments in modeling software, several new features are now accessible, opening a new level in HPLC method development. Many of these current possibilities in software assisted liquid chromatographic method modeling for analytical purposes are presented. Several modes of chromatography, including Reversed-Phase Liquid Chromatography (RPLC), Ion Exchange Chromatography (IEX), Hydrophobic Interaction Chromatography (HIC), and Hydrophilic Interaction Liquid Chromatography (HILIC) are explained in detail. For all these chromatographic modes, the most important variables for tuning retention and selectivity are exposed. Beside the industrial and practical benefits of retention modeling, the possibilities in teaching and education are also illustrated. Finally, numerous representative industrial examples are shown, to highlight the benefits, time and cost savings offered by state-of-the-art software assisted HPLC method development."--Publisher's website

Analytical Chemistry · 1990

Computer simulation (based on a linear-elution-strength approximation) as an aid for optimizing separations by programmed-temperature gas chromatography

D. E. Bautz, J. W. Dolan, W. D. Raddatz, L. R. Snyder

If the dependence of retention on temperature is specified for the various components of a sample in isothermal gas chromatography (GC), it is possible to predict retention, bandwidth, and resolution for programmed-temperature GC separations as a function of experimental conditions. The use of a linear-elution-strength (LES) approximation for isothermal retention allows these predictions to be carried out more easily and conveniently, in turn facilitating rapid simulations with a personal computer. This approach to GC method development appears promising, especially if segmented-temperature programs are used. The LES approximation also provides added insight into how different factors affect separation in programmed-temperature GC.

Journal of Pharmaceutical and Biomedical Analysis · 2020

Updating the European Pharmacopoeia impurity profiling method for terazosin and suggesting alternative columns

Dániel Enesei, Imre Kapui, Szabolcs Fekete, Róbert Kormány

This work was motivated by the demand of European Directorate for the Quality of Medicines and HealthCare (EDQM). A new liquid chromatographic (LC) method was developed for terazosin impurity profiling to replace the old European Pharmacopoeia (Ph. Eur.) method. This new method is published as part of the new Ph. Eur. monograph proposal of terazosin in Pharmeuropa issue 32.2. The aim of the method renewal was to cut the analysis time from 90 min (2 × 45 min) down to below 20 min. The Ph. Eur. monograph method is based on two different chromatographic separations to analyze the specified impurities of terazosin. The reason for the two methods is that two of the impurities are not sufficiently retained in reversed phase (RP) conditions, not even with 100% water as eluent. Therefore, next to RP, an ion-pair (IP) chromatographic method has to be applied to analyze those two impurities. With our new proposed method it was possible to appropriately increase the retention of the two critical compounds using alternative stationary phases (instead of a C18 phase which is suggested by the Ph. Eur. method). Applying a pentafluoro-phenyl (PFP) stationary phase, it was feasible to separate and adequately retain all the impurities. The detection wavelength was also changed compared to the Ph. Eur. method and is now appropriate for the detection and quantification of all impurities using perchloric acid in the mobile phase at low pH. Another goal of the present study was to develop a generic workflow and to evaluate the chromatographic resolution in a wide range of method variables and suggest some replacement columns for terazosin impurity profiling. Retention modeling was applied to study the chromatographic behavior of the compounds of interest and visualize resolution for the different columns, where a given criterion is fulfilled. A zone (set of chromatographic conditions) of a robust space could be then quickly identified by the overlay of the individual response surfaces (resolution maps). It was also demonstrated that two columns from different providers (Kinetex F5 and SpeedCore PFP) can be used as replacement columns, providing sufficient resolution at the same working point and a high degree of robustness.

Journal of Chromatography B: Biomedical Sciences and Applications · 1997

Computerized optimization of the high-performance liquid chromatographic enantioseparation of a mixture of 4-dinitrophenyl amino acids on a quinine carbamate-type chiral stationary phase using drylab

Michael Lämmerhofer, Paolo Di Eugenio, Imre Molnár, Wolfgang Lindner

A method is proposed for the sensitive chiral analysis of amino acid enantiomers by high-performance liquid chromatography (HPLC). Thus the enantiomers of a mixture of seven racemic amino acids were resolved as their DNP derivatives from each other and from the peak of the hydrolyzed reagent, employing a quinine carbamate-based chiral anion exchange-type chiral stationary phase (CSP) and aqueous buffered mobile phases. However, the initial isocratic chromatogram yielded many peak overlaps although the corresponding enantiomers were well resolved. Therefore, the separation of the complex mixture had to be optimized; we utilized the commercial computer method development software drylab. First, the influence of the manifold mobile phase parameters and chromatographic conditions (pH, type and content of organic modifier, buffer concentration, temperature, type of co-ion, etc.) on retention and resolution was studied by isocratic elution. Furthermore, with such optimized conditions linear and multi-segmented organic modifier and buffer salt gradients, respectively, were simulated with the computer program and experimentally verified. Average errors of prediction of retention times lay between 2 and 8%. Finally, a highly improved HPLC gradient method resulted in almost all components being baseline separated and equally spaced and accelerated by a factor of more than 3 compared to the initial run.

Analytical Chemistry · 1977

Liquid chromatography of ionogenic substances with nonpolar stationary phases

Csaba Horváth, Wayne Melander, Imre Molnár

The effect of solute ionization on the retention of weak acids, bases, and ampholytes on octadecylsilica was investigated both theoretically and experimentally. The retention was attributed to a reversible association of the solutes with the hydrocarbonaceous ligand of the stationary phase. A phenomenological treatment of the corresponding equilibria was developed for various types of ionogenic substances. The energetics of the association process was analyzed in a rigorous fashion in the light of the solvophobic theory and a semi-empirical extension of the Debye-Hiickel theory to high ionic strength. The predicted effect of solute ionization on the capacity factors was substantiated by experimental data. The observed dependence of the capacity factors on the ionic strength of the eluent and the hydrophobic surface of the solute molecules showed good agreement with the theory. The advantages of the technique in the separation of biological substances are illustrated.

Journal of Chromatography B: Biomedical Sciences and Applications · 1977

Rapid separation of urinary acids by high-performance liquid chromatography

Imre Molnár, Csaba Horváth

Over a hundred acidic urinary constituents were separated within 30 min by using 5-μm octadecyl-silica columns and gradient elution with increasing acetonitrile concentration in dilute aqueous phosphoric acid solution at 70°. The column effluent was monitored with a UV detector at 280 nm or with a fluorescence detector at 260 nm excitation and 340 nm emission wavelengths. The high sensitivity and speed of analysis, the excellent reproducibility and adequate resolution obtained suggest that this technique may be useful to obtain metabolic profiles in routine clinical work.

John Wiley · 2007

High-performance gradient elution: the practical application of the linear-solvent-strength model

Lloyd R. Snyder, John W. Dolan

Journal of Pharmaceutical and Biomedical Analysis · 2020

Development of a generic reversed-phase liquid chromatography method for protein quantification using analytical quality-by-design principles

Julian Kopp, Florian B. Zauner, Andreas Pell, Johanna Hausjell, Diana Humer, Julian Ebner, Christoph Herwig, Oliver Spadiut, Christoph Slouka, Reinhard Pell

Biopharmaceutical drug substances are generally produced using fermentation technology and are subsequently purified in the following downstream process. For the determination of critical quality attributes (CQAs), such as target protein titer and purity, monitoring tools are required before quality control analysis. We herein present a novel reversed phase liquid chromatography method (RPLC), which enables facile and robust protein quantification during upstream and downstream processing of intracellularly produced proteins in E. coli. The overall goal was to develop a fast, robust and mass spectrometry compatible method which can baseline resolve and quantify each protein of interest. Method development consisted of three steps, oriented on an Analytical Quality by Design (AQbD) workflow: (i) the stationary phase as primary parameter was chosen based on state-of-the art technology thus minimizing protein on-column adsorption and providing high efficiency, (ii) secondary parameters (i.e. gradient conditions and column temperature) were optimized applying chromatographic modeling, and (iii) the established Method Operable Design Region (MODR) was challenged and confirmed during robustness testing, performed in-silico and experimentally by a Design of experiment (DoE) based approach. Finally, we validated the RPLC method for pivotal validation parameters (i.e. linearity, limit of quantification, and repeatability) and compared it for protein quantification against a well-established analytical methodology. The outcome of this study shows (i) a protocol for RPLC development using an AQbD principle for new method generation and (ii) a highly versatile RPLC method, suited for quick and straightforward recombinant protein titer measurement being applicable for the detection of a broad range of proteins.